C1DZ--Renovate Sterile Processing Service
- Status
- Closed (archived notice)
- Agency
- United States Department of Veterans Affairs
- Office
- Greenwood Village, USA
- Notice type
- Presolicitation
- Solicitation number
- 36C25921R0003
- NAICS
- 541330 - Engineering Services
- PSC
- C1DZ - ARCHITECT AND ENGINEERING- CONSTRUCTION: OTHER HOSPITAL BUILDINGS
- Category
- Construction Related Services (4.2)
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Posted
- 2020-11-09
- Deadline
- 2020-11-20
- Place of performance
- Salt Lake City, 84148
Description
AMENDMENT 0001 The purpose of this amendment it to: 1. Provide RFI - Question and Answers 2. Extend CLOSING date FROM: Nov. 17, 2020 TO: Nov. 20, 2020 at 2:00pm MT. All other terms and conditions remain unchanged. Pre-SOLICITATION: A&E - Renovate Sterile Processing Service / 660-21-100 DESCRIPTION: This is a Pre-Solicitation Notice for the establishment of an Architect-Engineering (A-E) contract with services to be performed at the Salt Lake City VA Medical Center, 500 Foothill Dr. Salt Lake City, UT. This requirement is being set-aside to Small Disabled Veteran Owned Small Business (SDVOSB) firms. THIS ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSAL; NO SOLICITATION PACKAGE WILL BE ISSUED UNTIL AFTER AN EVALUATION HAS BEEN MADE ON THE PROVIDED SF-330s. The SF-330 can be downloaded through the GSA Forms Library at: http://www.gsa.gov/portal/forms/type/TOP, scroll down to locate and click on the SF-330 hyperlink entitled, Architect-Engineer Qualifications. Please note: Funds are not presently available for this contract. The Government s obligation under this contract is contingent upon the availability of appropriated funds from which payment for contract purposes can be made. No legal liability on the part of the Government for any payment may arise until funds are made available to the Contracting Officer for this contract and until the Contractor receives notice of such availability. Magnitude of Construction is between $1,000,000 and $5,000,000. Written questions pertaining to this requirement should be submitted no later than 2:00 p.m. Mountain Time (MT), Tuesday, November 3, 2020. Interested firms should submit their current SF-330, Parts I and II, to rebeca.hinz@va.gov. The SF-330s are due no later than 2:00 p.m. Mountain Time (MT), Tuesday, November 17, 2020. SCOPE OF WORK: Architect Engineer (A/E) is to provide professional services to perform investigative services for compliance with latest VHA design guides and directives to include but not necessarily limited to VHA Directive 1116 (Sterile Processing Services), PG-18-12 (Sterile Processing Design Guide), and VHA Directive 7704 (Emergency Eyewash) for the Sterile Processing Service (SPS) at the Salt Lake City VA Medical Center 500 Foothill Drive, Salt Lake City, UT 84148. The project area is located in Building 14 and is approximately 10,000 sq. ft. The A/E shall perform all investigations necessary to thoroughly evaluate the area including interviewing knowledgeable staff impacted by this project. The A/E shall consider all SPS work processes to create an efficient space supportive of work processes to ensure all functionality, safety, infection control, and sterilization requirements are being met. The A/E design basis should provide an analysis of the decontamination area, preparation + pack area, sterile storage area, breakroom area, locker rooms, and other necessary support areas. The A/E design basis shall also include an engineering assessment (electrical, mechanical, structural, etc.), architectural analysis, and compliance with applicable VHA Directives, VHA Design Guides, and VHA Memorandums. The A/E shall provide a renovated floor plan that provides an efficient space supportive of SPS processes and complies with SPS requirements including applicable VHA Directives, VHA Design Guides, and VHA Memorandums. Pending results of the A/E investigation, reconfiguration of the decontamination area, preparation + pack area, sterile storage area, breakroom area, locker rooms, and other necessary support areas may be required. Design shall account for movement of the location of the dumbwaiters. The new proposed location of the dumbwaiters is available on request by A/E. Design shall include upgrading finishes to meet VHA standards. In the event large scale equipment that may need to be relocated, i.e., cart washer or other sterilizing equipment, A/E shall propose alternatives to wall systems that will comply with VHA requirements as well as allowing for ease of the large-scale replacement. Proposed updates shall also provide compliant workspaces meeting VHA HVAC requirements. A/E shall design corrections for utilities that are used for the SPS area for code compliance as well as replace if due to past life expectancy of utility. Analysis shall be done by A/E on whether panel rooms can be enlarged as part of the SPS area reconfiguration due to current panel rooms not meeting code clearance requirements due to undersized electrical panel rooms. The electrical panels and transformers located in panel rooms for this area are circa 1983 so past life expectancy. In addition, current panel rooms do not meet clearance requirements i.e. there are currently transformers located under panels and panels do not meet clearance requirements due to wall location or adjacency of other panels. Panel room doors opening into corridors need upgraded to self-locking mechanism. The A/E shall propose an appropriate temporary facility that meets VHA SPS requirements, addresses transportation of SPS materials to and from the OR located in building 14, and limits the need for retraining VA staff on the temporary SPS equipment to be used during the construction period. A/E shall also furnish design services for site location and site preparation including but not limited to utilities and other temporary facilities necessary for this project. NOTE: Design will be investigated for code and VHA design guidelines compliance. Applicable design requirement documents are located on the VA Technical Information Library website https://www.cfm.va.gov/til/catalog.asp and VA CEOSH website http://vaww.hefp.va.gov/occupational-safety-health. The A/E is to coordinate and cooperate with all third-party reviews and come to a resolution on all noted deficiencies by third-party reviews. Design is to follow all information including but not limited to Design and Construction Procedures (PG-18-3) , Design Submission Instructions (PG-18-15) as outlined in VA Technical Information Library located at http://www.cfm.va.gov/TIL/cPro.asp unless otherwise approved in writing by VA. Please note, the VA is its own Authority Having Jurisdiction (AHJ) and therefore is not necessarily required to comply with the requirements of other AHJs with which the A/E firm may have worked. NOTE: Each phased design submission must have that percentage completion level done for all disciplines involved in design. For example, it is not acceptable for the AE to submit a 35% deliverable without also having the architectural, and all other engineering disciplines, etc. also at the respective percentage of completion. Contractor shall place emphasis on cost and scope management. An estimate of construction cost based on level of design detail will be required at each design phase. Refer to the appended A/E Submission Instructions for Minor and NRM Construction Program (VA Guide PG-18-15) for minimum deliverable requirements at each phase. Also include any other submittal requirements detailed in this SOW. The NAICS code for this project is 541330 Engineering Services. The current small business size standard for 541330 is $16.5 million. OFFERORS WILL BE EVALUATED ON THE FOLLOWING CRITERIA: The submitted SF-330s will be evaluated on the following criteria: This acquisition will be in accordance with FAR Part 36.602-1 and VAAR Part 836.601-1. The following evaluation criteria will be used to evaluate SF-330 technical proposals: The A/E must demonstrate its qualifications with respect to the published evaluation criteria for all services. Evaluation Criteria (1) through (4) are considered most important and equal among themselves; Criteria (5) through (7) are of slightly less importance than (1) through (4) but are equal value among themselves. Professional qualifications necessary for satisfactory performance of required services; Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials; Capacity to accomplish the work in the required time; Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules; Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project. Use of Service-Disabled Veteran Owned Small businesses. Experience in construction period services. Criterion1 - Professional Qualifications necessary for satisfactory performance of required services. Offerors will be evaluated in terms of the qualifications, competence and experience of the key personnel and technical team proposed to accomplish this work. Additionally, offerors will be evaluated on their record of working together as a ream. Key personnel are individuals who will have major contract or project management responsibilities and/or will provide unusual or unique expertise. Provide a licensed and/or certified workforce in all the following disciplines - Architecture, Interior Design, Civil, Structural, Mechanical & HVAC, Electrical, Fire Protection Engineering, LEAN/Six Sigma, LEED/Green Globes and AAMI. Lead designer in each discipline shall be registered but does not have to be registered in the particular state of this project. Submission requirements: Provide resumes for all proposed key personnel. Resumes are limited to one page each and should cite project specific experience and indicate proposed role in this contract. Provide professional registration, certification, licensure and/or accreditation. Indicate participation of key personnel in example projects in the SF-330 Part 1 Section G. Criterion 2 - Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Offerors will be evaluated on specialized experience and technical competence, to include offeror s proposed personnel, in the performance of services similar to those anticipated under this contract with regard to: Specialized knowledge of medical equipment sterilization processes and designs, transport systems for supplies and instruments, hospital infection control, and space planning. Also, vendor should be familiar with VA/AAMI/ANSI/ASME/ASHRAE/CDC/NFPA/OSHA codes and guides listed in the SPS Design Guide (pg. 18-12). Submission requirements: Provide up to five (5) projects completed or substantially completed within the past five (5) years that best illustrate specialized experience of the proposed team in the areas outlined above. Example projects shall note project s square footage. All projects provided in the SF-330 must be completed by the office/branch/regional office/individual team member proposed to manage and/or perform work under this contract. To enable verification, firms should include the DUNS number along with each firm name in the SF-330 Part 1, Section F Item 25 Firms from Section C Involved in this Project, block (1). Include a contract number or project identification number in block 21. Include an e-mail address, and phone number for the point of contact in block 23(c). Include in the project description the contract period of performance, award contract value, current contract value, a summary of the work performed that demonstrates relevance to specialized experience as outlined above. If the contractor served as a subcontractor on a project, indicate the value of the work they provided towards the performance of the overall project. If a project was performed by a joint venture, and not all joint venture partners are on the team proposed for this contract, the offeror/team should specifically address the work performed by the joint venture partner offering/teaming on this contract. Likewise, if the offeror/team member worked as a subcontractor on a project, the description should clearly describe the work actually performed by the offeror/team member and the roles and responsibilities of each on the project, rather than the work performed on the project as a whole. If the project description does not clearly delineate the work performed by the entity/entities offering/teaming on this contract, the project could be eliminated from consideration. NOTE: If the Offeror is a joint venture, information should be submitted as a joint venture; however, if there is no information for the joint venture, information should be submitted for either joint venture partner, not to exceed a total of five (5) projects for this criterion. Projects shall be submitted on the SF-330. For submittal purposes, a task order on an IDIQ contract is considered a project, as is a stand-alone contract award. Do not list an IDIQ contract as an example of a completed project. Instead, list relevant completed task orders or stand-alone contract awards that fit within the definition above. Examples of project work submitted that do not conform to this requirement will not be evaluated. Failure to provide requested data, accessible points of contact, or valid phone numbers could result in a firm being rated lower. All information for Criterion 2 should be submitted in Part 1, Section F of the SF-330. The Government WILL NOT consider information submitted in addition to Part 2, Section F in evaluating Criterion 2. Criterion 3 - Capacity to accomplish the work in the required time. Firms/teams will be evaluated in terms of their ability to plan for and manage work under the contract and capacity to accomplish the work in the required time, to include capacity within the key disciplines required by this project. Additionally, offerors will be evaluated on the volume of work awarded by the VA during the 12 months before the closing date. Submission requirements: Describe the firm s ability to concurrently perform and manage multiple projects in different locations to meet aggressive schedules, multiple disciplines, and control costs and the firm s capacity to accomplish multiple projects simultaneously. Criterion 4 - Past Performance. Offerors will be evaluated on past performance with Government agencies and private industry in terms of work quality, compliance with schedules, cost control, and stakeholder/customer satisfaction. Additionally, offerors will be evaluated on the reputation and standing of the firm and its principals with respect to professional performance, general management, and cooperativeness. Offerors will be also evaluated on their record of significant claims against the firm. Evaluating past performance and experience will include information provided in Past Performance Questionnaires (PPQs) or CPARS/ACASS for Criterion 1 projects and may include other information provided by the firm, customer inquiries, Government databases, and other information available to the Government including contacts with points of contact in other criteria. Failure to provide requested data, accessible points of contact, or valid phone numbers could result in a firm being rated lower. NOTE: Past performance information for projects listed under Criterion 1. Submission requirements: SUBMIT A COMPLETED CPARS/ACASS EVALUATION FOR EACH PROJECT UNDER CRITERION 1. IF THERE IS NOT A COMPLETED CPARS/ACASS EVALUATION, the Past Performance Questionnaire (PPQ) included in this notice is provided for the offeror or its team members to submit to the client for each project the offeror includes under Criterion 1. AN OFFEROR SHALL NOT SUBMIT A PPQ WHEN A COMPLETED CPARS/ACASS IS AVAILABLE. IF A CPARS/ACASS EVALUATION IS NOT AVAILABLE, ensure correct phone numbers and email addresses are provided for the client point of contact. Completed PPQs should be submitted with your SF-330. If the offeror is unable to obtain a completed PPQ from a client for a project(s) before the response date set forth in this notice, offerors should complete and submit with their responses the first page of the PPQ (Attachment), which will provide contract and client information for the respective project(s). Offerors may submit a PPQ previously submitted under a different Notice/RFP (legible copies are acceptable) if it is on the same form as posted with this Synopsis. Offerors should follow up with clients/references to ensure timely submittal of questionnaires. If requested by the client, questionnaires may be submitted directly to the Government's point of contact, Network Contracting Office 19, Attn: Rebeca Hinz via email at rebeca.hinz@va.gov prior to the response date. Offerors shall not incorporate by reference into their response PPQs or CPARS previously submitted in response to other A/E services procurements. However, this does not preclude the Government from utilizing previously submitted PPQ information in the past performance evaluation. Also, submit information regarding whether any significant claims have been filed against the offeror. Criterion 5 - Location in the general geographical area (Cheyenne, WY) and knowledge of the (Cheyenne, WY); provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project. Provided that the application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the contract, firms/teams will be evaluated on the locations of their office or offices that will be performing the work under this contract. Submission requirements: Indicate firms/teams location, including main offices, branch offices and any sub consultants offices and demonstrate how this will be advantageous to the Government. Criterion 6 - Use of Service-Disabled Veteran Owned Small businesses. The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors will be evaluated. Submission requirements: Indicate Service-Disabled Veteran Owned Small Business (SDVOSB) firms/teams proposed to be used on this project. Criterion 7 - Experience in construction period services. Professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates will be evaluated. Submission requirements: Indicate from projects submitted in Criteria #2 the extent and magnitude of the construction period services regarding the areas stated above included in those projects. SELECTION INTERVIEW: Interviews shall be scheduled with firms slated as the most highly qualified. Firms slated for interviews will be asked a series of established questions. Elaborate presentations are not desired. GENERAL INFORMATION: All design and work will conform to the current edition of the VA Master Specifications and VA Design Standards as published at the following site: www.cfm.va.gov; ASME, OSHA, IBC 2009, NFPA and NEC building codes and standards. Coordinate all work through the COR of Facilities Management Service. Contractor is responsible for all cleanups and refuse disposal throughout the construction period. The A-E firm will prepare drawings and specifications in sufficient detail such that qualified outside General Contracting companies can prepare accurate and timely proposals for the desired construction work. Microsoft Project scheduling and management software will be used by both the A-E and Contractors to allow for regular tracking of schedules and work by the VA Medical Center. Schedules with MS Project will be regularly sent to the COR upon project initiation and whenever significant changes occur in the schedule. TheContacts
- Rebeca Hinz, Contract Specialist
Email and phone are in the source notice.
More from United States Department of Veterans Affairs posted in November 2020