<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/104999052904323912" -->

---
title: H245--Hot Water Boiler Maintenance (36C24121Q0019) | Closed - MatchAwards
description: H245--Hot Water Boiler Maintenance. United States Department of Veterans Affairs. Solicitation 36C24121Q0019. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. Deadline 2020-10-14. THIS SOURCES SOUGHT/REQUEST FOR...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/104999052904323912
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: H245--Hot Water Boiler Maintenance (36C24121Q0019) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/104999052904323912
og:description: H245--Hot Water Boiler Maintenance. United States Department of Veterans Affairs. Solicitation 36C24121Q0019. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. Deadline 2020-10-14. THIS SOURCES SOUGHT/REQUEST FOR...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# H245--Hot Water Boiler Maintenance

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

TOGUS, USA

Notice type

Sources Sought

Solicitation number

36C24121Q0019

NAICS

[811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance](/groups/1092)

PSC

H245 - EQUIPMENT AND MATERIALS TESTING- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT

Posted

2020-10-08

Deadline

2020-10-14

Place of performance

West Roxbury, 02132

## Description

THIS SOURCES SOUGHT/REQUEST FOR INFORMATION IS ISSUED FOR INFORMATION AND PLANNING PURPOSES ONLY AND IS NOT CONSIDERED A SOLICITATION. The purpose of this sources sought/RFI is to gain knowledge of businesses that are capable of satisfying the following work requirements: STATEMENT OF WORK Annual Boiler Maintenance 1.0 Scope of Work The contractor will perform annual boiler maintenance and inspections at the Boston Healthcare System, West Roxbury Division. Contractor is responsible for all labor, materials, tools and special equipment required to perform the work. Equipment: Building 20 PH (3) Aerco 750 Natural Gas Fisher House (1) Burnham P810HNEI-L2 Natural Gas 2.0 Performance Requirements Perform annual boiler maintenance, inspection and testing in accordance with manufactures recommendations to complete items listed in the attached boiler maintenance checklist. All work shall be performed during normal working hours, which exclude Saturdays, Sundays, Holidays and the hours prior to 7:00 A.M. and after 6:00 P.M. The Contractor shall complete the following tasks: Shut down boiler at controls & fuel source Drain down boiler & review manufacture procedures Check boiler for corrosion, pitting, scale, blisters, bulges, and soot. Inspect refractory / heat exchanger Clean per manufacture recommendations Check the gas supply piping, regulators, isolation valves for wear or leaks Test the high/low gas pressure switch, calibrate if needed Verify the operation of the flow switch Inspect and clean burner, igniter assembly Inspect and clean fan Inspect flue and flue damper Run fan and check for vibration Inspect for cleanness Inspect/check wiring and connections Inspect /check operation of low water cutoff Inspect / check operation of operating and limit controls Verify water level in boiler Test safety/relief valve Adjust electrodes/igniters Perform combustion test and adjust as needed for efficiency. Review operating procedures with operation set-up Log operating conditions Comments / Action items / Notes Period of Performance: A base period of 2 consecutive weeks plus four (4) option periods that will be 2 weeks each. The options may or may not be exercised. Place of Performance: 1400 VFW Parkway, West Roxbury, MA, 02132 Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought notice are not considered adequate responses for a solicitation announcement. Responses to this sources sought/RFI are due by 1 pm EST time on October 14, 2020\. Responses to this notice shall be submitted via email to issa.shawki@va.gov. Telephone responses shall not be accepted. If a solicitation is issued it shall be announced at a later date, and all interest parties must response to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The NAICS code for this requirement is 811310 and a small size standard of $8,000,000.00 

<!-- mobian-agent-ad sponsored="true" id="ebc2bafe-016b-4181-ac8b-cf284a7cbf71" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* John Shawki, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/abaaddb89cb34ddf9f46073a3ac52fec/view)

[More from United States Department of Veterans Affairs posted in October 2020](/department%5Fof%5Fveterans%5Faffairs/archive/2020-10)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)

```json
{"@context":"https://schema.org","@type":"Demand","name":"H245--Hot Water Boiler Maintenance","description":"THIS SOURCES SOUGHT/REQUEST FOR INFORMATION IS ISSUED FOR INFORMATION AND PLANNING PURPOSES ONLY AND IS NOT CONSIDERED A SOLICITATION. The purpose of this sources sought/RFI is to gain knowledge of businesses that are capable of satisfying the following work requirements: STATEMENT OF WORK Annual Boiler Maintenance 1.0 Scope of Work The contractor will perform annual boiler maintenance and inspections at the Boston Healthcare System, West Roxbury Division. Contractor is responsible for all labor, materials, tools and special equipment required to perform the work. Equipment: Building 20 PH (3) Aerco 750 Natural Gas Fisher House (1) Burnham P810HNEI-L2 Natural Gas 2.0 Performance Requirements Perform annual boiler maintenance, inspection and testing in accordance with manufactures recommendations to complete items listed in the attached boiler maintenance checklist. All work shall be performed during normal working hours, which exclude Saturdays, Sundays, Holidays and the hours prior to 7:00 A.M. and after 6:00 P.M. The Contractor shall complete the following tasks: Shut down boiler at controls \u0026 fuel source Drain down boiler \u0026 review manufacture procedures Check boiler for corrosion, pitting, scale, blisters, bulges, and soot. Inspect refractory / heat exchanger Clean per manufacture recommendations Check the gas supply piping, regulators, isolation valves for wear or leaks Test the high/low gas pressure switch, calibrate if needed Verify the operation of the flow switch Inspect and clean burner, igniter assembly Inspect and clean fan Inspect flue and flue damper Run fan and check for vibration Inspect for cleanness Inspect/check wiring and connections Inspect /check operation of low water cutoff Inspect / check operation of operating and limit controls Verify water level in boiler Test safety/relief valve Adjust electrodes/igniters Perform combustion test and adjust as needed for efficiency. Review operating procedures with operation set-up Log operating conditions Comments / Action items / Notes Period of Performance: A base period of 2 consecutive weeks plus four (4) option periods that will be 2 weeks each. The options may or may not be exercised. Place of Performance: 1400 VFW Parkway, West Roxbury, MA, 02132 Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought notice are not considered adequate responses for a solicitation announcement. Responses to this sources sought/RFI are due by 1 pm EST time on October 14, 2020. Responses to this notice shall be submitted via email to issa.shawki@va.gov. Telephone responses shall not be accepted. If a solicitation is issued it shall be announced at a later date, and all interest parties must response to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The NAICS code for this requirement is 811310 and a small size standard of $8,000,000.00","url":"https://matchawards.com/department_of_veterans_affairs/posts/104999052904323912","identifier":"36C24121Q0019","category":"811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"H245 - EQUIPMENT AND MATERIALS TESTING- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT"}],"availabilityStarts":"2020-10-08","availabilityEnds":"2020-10-14","areaServed":"West Roxbury, 02132","sameAs":"https://sam.gov/opp/abaaddb89cb34ddf9f46073a3ac52fec/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"}]}
```