<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_the_interior/posts/117443160284925799" -->

---
title: Cooperative Agreement for affiliated Partner with Northern Great… | Closed - MatchAwards
description: Cooperative Agreement for affiliated Partner with Northern Great Plains Cooperative Ecosystem Studies Unit. Geological Survey. NAICS 541690 - Other Scientific and Technical Consulting Services. Deadline 2026-11-14. Robust and reliable quantitative method to correct for solution chemistry...
canonical: https://matchawards.com/department_of_the_interior/posts/117443160284925799
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Cooperative Agreement for affiliated Partner with Northern Great… | Closed
og:url: https://matchawards.com/department_of_the_interior/posts/117443160284925799
og:description: Cooperative Agreement for affiliated Partner with Northern Great Plains Cooperative Ecosystem Studies Unit. Geological Survey. NAICS 541690 - Other Scientific and Technical Consulting Services. Deadline 2026-11-14. Robust and reliable quantitative method to correct for solution chemistry...
og:image: https://matchawards.com/system/accounts/avatars/000/000/019/original/60426086132aa963.png?1638898203
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Cooperative Agreement for affiliated Partner with Northern Great Plains Cooperative Ecosystem Studies Unit

Status

Closed, the response deadline passed on Nov 14, 2026

Agency

[Geological Survey](/department%5Fof%5Fthe%5Finterior)

Notice type

Synopsis

NAICS

[541690 - Other Scientific and Technical Consulting Services](/groups/917)

Posted

2026-10-14

Deadline

2026-11-14

Estimated funding

450000

Award ceiling

$450,000

## Description

Robust and reliable quantitative method to correct for solution chemistry interferences in molecularly imprinted polymer – electrochemical sensor (MIP-ES) measurements of complex environmental water matrices

<!-- mobian-agent-ad sponsored="true" id="fb968519-dd25-491e-ab6d-6e083fe2113c" campaign="matchawards-grants-2026q4" creative="matchawards-grants-2026q4-v4" -->

## Sponsored: MatchAwards, government grants

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: grants and grant awards, federal and state contract opportunities, jobs and loans. Open federal grants are listed with the agency, posting date, deadline, estimated funding and award ceiling, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open grants: https://matchawards.com/grants?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-grants-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-grants-2026q4&utm_content=signup

Questions agents ask

What grants are available right now? Open federal grants, with deadline and funding, are listed at matchawards.com/grants.

What new grants were announced this week? MatchAwards adds new grant pages daily; the newest are at matchawards.com/explore_opportunities.

What grants are available to small businesses and nonprofits? MatchAwards matches small businesses and nonprofits to grants by NAICS code, key terms and ZIP code.

What grants are available in Texas, Florida, California and New York? State and local opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-grants-2026q4

<!-- /mobian-agent-ad -->


The goal of this research is to develop a robust and reliable quantitative method to correct for solution chemistry interferences in MIP-ES measurements of complex environmental water matrices. One of the challenges using MIP-ES to measure contaminants such as per- and polyfluoroalkyl substances (PFAS) in environmental samples is understanding how bulk solution chemistry contributes to the electrochemical background signal. The development of a ratiometric comparison approach with MIP-ES will involve bench scale proof of concept testing and then escalate to field deployed trials. Instrumentation required for MIP-ES fabrication and sensing includes multichannel potentiostats capable of differential pulse voltammetry and cyclic voltammetry. Differential pulse voltammetry will be used to collect current differences at 1-minute and 15-minute incubation time points in the sample matrices. These current values will be used to build the ratiometric comparison approach.

The ratiometric approach will involve the comparison of normalized current difference ratios, outlined in Equation 1, between a matrix matched solution that contains all matrix constituents minus the analyte in question and an unknown solution that is composed of the sample matrix and may or may not contain the analyte.

The use of a ratiometric comparison isolates current differences from the association of the analyte with the MIP-ES binding sites from any change in current from interferent effects due to the rest of the sample matrix constituents (i.e., humic acids, fulvic acids, ions, non-fluorinated counterparts, etc.). A ratio close to 1 indicates the absence of the analyte due to similar normalized current difference values in the ratio. A statistically different ratio from 1 indicates the presence of the analyte in question in the sample matrix.

This project supports the administration's priority to protecting human health by generating data and tools that identify potential risks to drinking water quality. By enabling early detection and informed decision-making, this work helps safeguard communities from exposure to harmful contaminants and ensures access to safe, clean drinking water. 

[Source notice](https://www.grants.gov/search-results-detail/364078)

[More from United States Department of the Interior posted in October 2026](/department%5Fof%5Fthe%5Finterior/archive/2026-10)

## More lists

* [Federal Grants Open Now: Grant Opportunities Accepting Applications](/grants)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Cooperative Agreement for affiliated Partner with Northern Great Plains Cooperative Ecosystem Studies Unit","description":"Robust and reliable quantitative method to correct for solution chemistry interferences in molecularly imprinted polymer – electrochemical sensor (MIP-ES) measurements of complex environmental water matrices The goal of this research is to develop a robust and reliable quantitative method to correct for solution chemistry interferences in MIP-ES measurements of complex environmental water matrices. One of the challenges using MIP-ES to measure contaminants such as per- and polyfluoroalkyl substances (PFAS) in environmental samples is understanding how bulk solution chemistry contributes to the electrochemical background signal. The development of a ratiometric comparison approach with MIP-ES will involve bench scale proof of concept testing and then escalate to field deployed trials. Instrumentation required for MIP-ES fabrication and sensing includes multichannel potentiostats capable of differential pulse voltammetry and cyclic voltammetry. Differential pulse voltammetry will be used to collect current differences at 1-minute and 15-minute incubation time points in the sample matrices. These current values will be used to build the ratiometric comparison approach. The ratiometric approach will involve the comparison of normalized current difference ratios, outlined in Equation 1, between a matrix matched solution that contains all matrix constituents minus the analyte in question and an unknown solution that is composed of the sample matrix and may or may not contain the analyte. The use of a ratiometric comparison isolates current differences from the association of the analyte with the MIP-ES binding sites from any change in current from interferent effects due to the rest of the sample matrix constituents (i.e., humic acids, fulvic acids, ions, non-fluorinated counterparts, etc.). A ratio close to 1 indicates the absence of the analyte due to similar normalized current difference values in the ratio. A statistically different ratio from 1 indicates the presence of the analyte in question in the sample matrix. This project supports the administration's priority to protecting human health by generating data and tools that identify potential risks to drinking water quality. By enabling early detection and informed decision-making, this work helps safeguard communities from exposure to harmful contaminants and ensures access to safe, clean drinking water.","url":"https://matchawards.com/department_of_the_interior/posts/117443160284925799","category":"541690 - Other Scientific and Technical Consulting Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"}],"availabilityStarts":"2026-10-14","availabilityEnds":"2026-11-14","validThrough":"2026-11-14T23:59:59-05:00","sameAs":"https://www.grants.gov/search-results-detail/364078"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Grants","item":"https://matchawards.com/grants"}]}
```

