UNIVERSITY OF ROCHESTER
- Agency
- United States Department of the Interior
- NAICS
- 541715 - Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology)
- Period start
- 2025-09-30
- Period end
- 2027-09-29
- Budget
- 150000.0
- Place of performance
- NEW YORK, UNITED STATES
Description
FEDERAL AGENCY NAME: DEFENSE ADVANCED RESEARCH PROJECTS AGENCY (DARPA), DEFENSE SCIENCES OFFICE (DSO) FUNDING OPPORTUNITY TITLE: YOUNG FACULTY AWARD (YFA) FUNDING OPPORTUNITY NUMBER: DARPARA2501CATALOG OF FEDERAL DOMESTIC ASSISTANCE (CFDA) NUMBER(S): 12.910 RESEARCH AND TECHNOLOGY DEVELOPMENTPROGRAM DESCRIPTION: DARPA IS SOLICITING INNOVATIVE RESEARCH PROPOSALS IN THE AREAS OF INTEREST TO THE FOLLOWING DARPA TECHNICAL OFFICES: DEFENSE SCIENCES OFFICE (DSO), INFORMATION INNOVATION OFFICE (I2O), MICROSYSTEMS TECHNOLOGY OFFICE (MTO), AND THE TACTICAL TECHNOLOGY OFFICE (TTO). FURTHER DETAIL REGARDING THE SPECIFIC TECHNICAL AREAS OF INTEREST CAN BE FOUND BELOW UNDER OPEN OFFICE TOPICS. PROPOSED RESEARCH SHOULD INVESTIGATE INNOVATIVE APPROACHES THAT ENABLE REVOLUTIONARY ADVANCES IN SCIENCE, DEVICES, OR SYSTEMS. SPECIFICALLY EXCLUDED IS RESEARCH THAT PRIMARILY RESULTS IN EVOLUTIONARY IMPROVEMENTS TO THE EXISTING STATE OF PRACTICE.ULTRALOW SIZE, WEIGHT, POWER, AND COST (SWAP-C) ACCELEROMETERS WITH HIGH SENSITIVITY ANDSTABILITY ARE ESSENTIAL COMPONENTS FOR NAVIGATION AND MOTION SENSING USED IN DRONES, UNMANNEDAERIAL VEHICLES (UAVS), AND SATELLITES, ESPECIALLY AS AN ALTERNATIVE POSITIONING, NAVIGATION, ANDTIMING (PNT) TECHNOLOGY FOR SITUATIONS WHERE GPS SIGNALS ARE JAMMED OR UNAVAILABLE. HOWEVER,THE STANDARD QUANTUM LIMIT (I.E. SHOT NOISE) LIMITS THE SENSITIVITY THAT CAN BE ATTAINED EVEN AT THETHERMOMECHANICAL LIMIT. CURRENT STATE OF THE ART, COMPACT ACCELEROMETERS HAVE A SENSITIVITY 30NG HZ1 2 (1NG 9.8*10-9M S2) OVER A 7KHZ BANDWIDTH THAT IS LIMITED BY THE SHOT NOISE OF THESYSTEM. ONE CAN IMPROVE THE SENSITIVITY BY USING SQUEEZED LIGHT TO READ OUT THE MECHANICALMOTION HOWEVER, OPTICAL SQUEEZING IS VERY SENSITIVE TO SYSTEM LOSS AND THE HIGHEST DEMONSTRATEDSQUEEZING IS ONLY 15DB (LAB DEMONSTRATION, NOT PRACTICAL). QUANTUM ACCELEROMETERS BASED ONATOMIC GASES ARE CHALLENGING TO MINIATURIZE AND ARE NOT MUCH BETTER THAN THE CLASSICAL OPTOMECHANICAL ONES.THE VISION OF THE PROPOSED WORK IS TO ENHANCE THE SENSITIVITY OF OPTOMECHANICAL ACCELEROMETERS BY 30DB USING WEAK VALUE AMPLIFICATION (WVA) AND ENABLE UNPRECEDENTED LEVELS OF INERTIAL NAVIGATION. IF THIS PROJECT IS SUCCESSFUL, COMPACT ACCELEROMETERS WITH SENSITIVITY OF 10PG HZ1 2 (1PG 9.8*10-12M S2) WILL BECOME A REALITY.THIS WILL ENABLE LONGER MISSIONS IN GPS DENIED ENVIRONMENTS, UNDERWATER, INDOORS, AND BELOW GROUND. THIS WORK WILL REDUCE THE UNCERTAINTY IN THE LOCATION OF A MISSION, I.E. THE CIRCULAR ERROR PROBABLE, AND WILL ENABLE LONGER DURATION MISSIONS IN SLOWER PLATFORMS. THESE RESULTS WILL ENABLE PRECISION SPACE NAVIGATION IN SMALL SPACECRAFT, IMPROVED SEISMOMETRY, AND INERTIAL NAVIGATION OF COMPACT VEHICLES.More from United States Department of the Interior posted in September 2025