<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_state/posts/112539836160506199" -->

---
title: 19GV1024Q0011 PMS-Kitchen Hood Fire Suppression System | Closed - MatchAwards
description: 19GV1024Q0011 PMS-Kitchen Hood Fire Suppression System. United States Department of State. Solicitation 19GV1024Q0011. Deadline 2024-06-13. Preventive Maintenance Contract Scope of Work For Kitchen hood fire suppression system United States Embassy Conakry -Guinea 2024 Exhibit A - - STATEMENT OF...
canonical: https://matchawards.com/department_of_state/posts/112539836160506199
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 19GV1024Q0011 PMS-Kitchen Hood Fire Suppression System | Closed
og:url: https://matchawards.com/department_of_state/posts/112539836160506199
og:description: 19GV1024Q0011 PMS-Kitchen Hood Fire Suppression System. United States Department of State. Solicitation 19GV1024Q0011. Deadline 2024-06-13. Preventive Maintenance Contract Scope of Work For Kitchen hood fire suppression system United States Embassy Conakry -Guinea 2024 Exhibit A - - STATEMENT OF...
og:image: https://matchawards.com/system/accounts/avatars/000/000/059/original/b1e87e8b0854e252.png?1638978695
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 19GV1024Q0011 PMS-Kitchen Hood Fire Suppression System

Status

Closed, the response deadline passed on Jun 13, 2024

Agency

[United States Department of State](/department%5Fof%5Fstate)

Office

WASHINGTON, USA

Notice type

Solicitation

Solicitation number

19GV1024Q0011

PSC

4931 - FIRE CONTROL MAINTENANCE AND REPAIR SHOP SPECIALIZED EQUIPMENT

Category

[Machinery & Components (5.1)](/categories/industrial-products-and-services/machinery-and-components)

Posted

2024-05-31

Deadline

2024-06-13

Place of performance

CONAKRY, Conakry 603, GUINEA

## Description

**Preventive Maintenance Contract**

**Scope of Work**

**For**

**Kitchen hood fire suppression system**

**United States Embassy**

**Conakry -Guinea**

**2024**

**Exhibit A - - STATEMENT OF WORK**

I. GENERAL INFORMATION:

The United States Embassy in Conakry requires professional services and contractor cost proposals to perform annual preventive maintenance and servicing of the kitchen hood fire suppression system installed at recreation facility, NOX AID ANNEX cafeteria.

<!-- mobian-agent-ad sponsored="true" id="71514616-37e2-4c34-845e-a3812076123f" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/machinery-and-components?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


II. PROJECT REQUIREMENTS:

 DESCRIPTION OF EQUIPMENT: The kitchen hood fire suppression system and its equipment are\*:

 \*_Please see attachment at the end of this sheet for more details_

1. ANSUL wet Chemical fire suppression system

III. GENERAL REQUIREMENTS:

The Contractor under this SOW will be responsible for labor, tools, and materials required to carry out all preventive maintenance as outlined in this SOW. Embassy staff has service manuals for kitchen hood suppression system on-site.

IV. SCOPE OF WORK - - KITCHEN HOOD SUPPRESSION SYSTEM- PREVENTIVE MAINTENANCE

Contractor shall provide all materials, supervision, labor, tools, and equipment to perform preventive maintenance. All personnel working in the vicinity shall wear and /or use safety protection while all work is performed. Any questions or injuries **shall** be brought to the attention of the Post Occupation Safety and Health Officer (POSHO). Material Safety Data Sheets (MSDS) shall be provided by the Contractor for all HAZMAT materials. Copies will be provided to the COR for approval.

If any discrepancies are found with the system that are **NOT** covered under this scope of work, then the contractor must provide the following:

1. Detailed report noting the discrepancy found.
2. Bill of Materials (BOM) to include component name, quantity, part #, and price for any repair material required and material lead time.
3. Price quote for repair labor.

SPECIFIC REQUIREMENTS:

All work shall be in conformance with NFPA 17 _Wet Chemical Extinguishing Systems_ or NFPA 17A _Dry Chemical Extinguishing Systems_

At a minimum, the following work must be completed: (All tasks are to be performed quarterly unless otherwise noted)

1. Activate one detector for each system.
2. Verify mechanical system operation.
3. Verify condition and operability of gas shutoff valve.
4. Verify electrical shutoff.
5. Inspect piping condition.
6. Check all piping supports.
7. Check all nozzles.
8. Install record tags.
9. Verify owner’s manual on site.
10. Inspect for any changes to the cooking equipment or kitchen layout that may affect the performance and reliability of the system.
11. Inspect and determine if hood and ducts are clean and free of grease.
12. Inspect condition of filters
13. Inspect and verify all detectors and nozzles are properly located.
14. Check nozzles are correctly aimed at equipment.
15. Compile a complete report of inspection.
16. Clean and lubricate all mechanical linkages and accessories.
17. The manual actuators are unobstructed.
18. The tamper indicators and seals are intact.
19. No obvious physical damage or condition exists that might prevent operation.
20. The pressure gauge(s), if provided, has been inspected physically or electronically to ensure it is in the operable range.
21. The nozzle blows off caps, where provided, are intact and undamaged.
22. During the inspection of the hoods, grease-removal devices, fans, ducts, or other appurtenances have an accumulation of grease, such components shall be cleaned.

V. TECHNICIAN REQUIREMENTS

Technician who performs maintenance on an extinguishing system shall be trained and shall have passed a written or online test. The certificate shall be issued by the manufacturer or testing organization.
  
  
**EQUIPMENT**

**MANUFACTURER**

**MAKE**

**MODEL**

**SPECIFICATION**

**LOCATION**

Fire suppression system

wet chemical

Korun.com

Professional- Turkey

ANSUL

R-102

3 Gallons Liquid Agent Restaurant Fire Suppression System. Wet Chemical Extinguishing System unit 16S6.

NOX USADI Cafeteria
  
  
## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3006dfb0541c44098237f7d37d12044c/download?api%5Fkey=null&token=)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e6fe86648b9b465aa1d4c99ea2455854/download?api%5Fkey=null&token=)

[Source notice](https://sam.gov/opp/4cdd1120912f43ad9e8ca532bf07da50/view)

[More from United States Department of State posted in June 2024](/department%5Fof%5Fstate/archive/2024-06)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)

```json
{"@context":"https://schema.org","@type":"Demand","name":"19GV1024Q0011 PMS-Kitchen Hood Fire Suppression System","description":"Preventive Maintenance Contract Scope of Work For Kitchen hood fire suppression system United States Embassy Conakry -Guinea 2024 Exhibit A - - STATEMENT OF WORK I. GENERAL INFORMATION: The United States Embassy in Conakry requires professional services and contractor cost proposals to perform annual preventive maintenance and servicing of the kitchen hood fire suppression system installed at recreation facility, NOX AID ANNEX cafeteria. II. PROJECT REQUIREMENTS: DESCRIPTION OF EQUIPMENT: The kitchen hood fire suppression system and its equipment are*: * Please see attachment at the end of this sheet for more details ANSUL wet Chemical fire suppression system III. GENERAL REQUIREMENTS: The Contractor under this SOW will be responsible for labor, tools, and materials required to carry out all preventive maintenance as outlined in this SOW. Embassy staff has service manuals for kitchen hood suppression system on-site. IV. SCOPE OF WORK - - KITCHEN HOOD SUPPRESSION SYSTEM- PREVENTIVE MAINTENANCE Contractor shall provide all materials, supervision, labor, tools, and equipment to perform preventive maintenance. All personnel working in the vicinity shall wear and /or use safety protection while all work is performed. Any questions or injuries shall be brought to the attention of the Post Occupation Safety and Health Officer (POSHO). Material Safety Data Sheets (MSDS) shall be provided by the Contractor for all HAZMAT materials. Copies will be provided to the COR for approval. If any discrepancies are found with the system that are NOT covered under this scope of work, then the contractor must provide the following: Detailed report noting the discrepancy found. Bill of Materials (BOM) to include component name, quantity, part #, and price for any repair material required and material lead time. Price quote for repair labor. SPECIFIC REQUIREMENTS: All work shall be in conformance with NFPA 17 Wet Chemical Extinguishing Systems or NFPA 17A Dry Chemical Extinguishing Systems At a minimum , the following work must be completed: (All tasks are to be performed quarterly unless otherwise noted) Activate one detector for each system. Verify mechanical system operation. Verify condition and operability of gas shutoff valve. Verify electrical shutoff. Inspect piping condition. Check all piping supports. Check all nozzles. Install record tags. Verify owner’s manual on site. Inspect for any changes to the cooking equipment or kitchen layout that may affect the performance and reliability of the system. Inspect and determine if hood and ducts are clean and free of grease. Inspect condition of filters Inspect and verify all detectors and nozzles are properly located. Check nozzles are correctly aimed at equipment. Compile a complete report of inspection. Clean and lubricate all mechanical linkages and accessories. The manual actuators are unobstructed. The tamper indicators and seals are intact. No obvious physical damage or condition exists that might prevent operation. The pressure gauge(s), if provided, has been inspected physically or electronically to ensure it is in the operable range. The nozzle blows off caps, where provided, are intact and undamaged. During the inspection of the hoods, grease-removal devices, fans, ducts, or other appurtenances have an accumulation of grease, such components shall be cleaned. V. TECHNICIAN REQUIREMENTS Technician who performs maintenance on an extinguishing system shall be trained and shall have passed a written or online test. The certificate shall be issued by the manufacturer or testing organization. EQUIPMENT MANUFACTURER MAKE MODEL SPECIFICATION LOCATION Fire suppression system wet chemical Korun.com Professional- Turkey ANSUL R-102 3 Gallons Liquid Agent Restaurant Fire Suppression System. Wet Chemical Extinguishing System unit 16S6. NOX USADI Cafeteria","url":"https://matchawards.com/department_of_state/posts/112539836160506199","identifier":"19GV1024Q0011","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"4931 - FIRE CONTROL MAINTENANCE AND REPAIR SHOP SPECIALIZED EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.1 Machinery \u0026 Components","url":"https://matchawards.com/categories/industrial-products-and-services/machinery-and-components"}],"availabilityStarts":"2024-05-31","availabilityEnds":"2024-06-13","validThrough":"2024-06-13T23:59:59-04:00","areaServed":"CONAKRY, Conakry 603, GUINEA","sameAs":"https://sam.gov/opp/4cdd1120912f43ad9e8ca532bf07da50/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"}]}
```