ClickCease MICHIGAN STATE UNIVERSITY – $248K, FY2026 | Award - MatchAwards

MICHIGAN STATE UNIVERSITY

Agency
United States Department of Commerce
NAICS
541715 - Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology)
Period start
2025-10-01
Period end
2026-09-30
Budget
248191.7
Place of performance
EAST LANSING, MICHIGAN 48824, UNITED STATES

Description

PURPOSE: THIS PROPOSAL IS COMPRISED OF THREE MAIN TASKS WITHIN THE DURATION OF ONE YEAR. THE PROJECT SCOPE INCLUDES ACQUISITION OF A NEW AND SOTA W-BAND VRLP SYSTEM, RIGOROUS VERIFICATION OF THE SYSTEM, AND EMPLOYMENT OF THE NEWLY OBTAINED VRLP SYSTEM FOR METROLOGY-INFORMED W-BAND LP CHARACTERIZATION OF MM-WAVE GAN TRANSISTORS WITHIN THE U.S. SUPPLY CHAIN. THE FOLLOWING EXPANDS UPON THE PROPOSED TASKS OF THIS PROJECT.ACTIVITIES TO BE PERFORMED: TASK 1: ACQUISITION OF A SOTA W-BAND VRLP SYSTEMTHE FIRST TASK OF THIS PROPOSED ONE-YEAR PROJECT IS THE ACQUISITION OF A SOTA W-BAND VRLP SYSTEM. BASED UPON EXTENSIVE RESEARCH INTO THE VENDORS WHICH CAN PROVIDE A COMMERCIAL SOLUTION AND COMPONENTS FOR THE PROPOSED MEASUREMENT SYSTEM, IT IS DETERMINED THAT MAURY MICROWAVE PROVIDES THE BEST SOLUTION FOR W-BAND VRLP WHICH INTEGRATES INTO MSU'S EXISTING RF MEASUREMENT LABORATORY.TASK 2: RIGOROUS VERIFICATION AND ANALYSISAFTER SUCCESSFUL ACQUISITION OF THE W-BAND ON-WAFER VRLP MEASUREMENT SYSTEM DESCRIBED IN THE PREVIOUS SECTION, THE MSU TEAM WILL RIGOROUSLY QUALIFY THE COMPLETE SYSTEM USING STANDARD TECHNIQUES DEVELOPED IN PREVIOUS WORK [4]. THE MSU TEAM WILL ALSO PERFORM METROLOGY RELATED ANALYSES ON THE SYSTEM COMPONENTS INCLUDING THE AMPLIFIERS, THE SIGNAL SOURCES, AND THE FREQUENCY DOWN-CONVERTING DEVICES.TASK 3 TASK 3: METROLOGY-INFORMED VRLP CHARACTERIZATION OF U.S. MM-WAVE GAN TECHNOLOGIESTHE ON-WAFER W-BAND VRLP SYSTEM THAT WILL BE ESTABLISHED AND QUALIFIED AT MSU CAN BE USED BY THE U.S. MM-WAVE GAN INDUSTRY10AND WILL ENABLE RIGOROUS CHARACTERIZATION AND12 BENCHMARKING OF SOTA TRANSISTORS AND INTEGRATED CIRCUITS. AS DISCUSSED IN THE PREVIOUS SECTIONS, IT IS CRITICAL TO USE THE NIST MTRL CALIBRATION ALGORITHM WITH WELL-DESIGNED ON-WAFER STRUCTURES TO ENSURE PRECISE MEASUREMENTSEXPECTED OUTCOMES: ESTABLISHMENT OF U.S-BASED, METROLOGY-INFORMED W-BAND VRLP SYSTEM AT MSU. SUBSTANTIAL IMPROVEMENT IN CALIBRATION ACCURACY FOR W-BAND MEASUREMENTS. RIGOROUS CHARACTERIZATION OF U.S MM-WAVE GAN DEVICES.INTENDED BENEFICIARIES: THE INTENDED BENEFICIARIES OF THIS AWARD WOULD BE U.S GAN FOUNDRIES & SEMICONDUCTOR COMPANIES U.S DEFENSE & AEROSPACE SECTOR ACADEMIC RESEARCH INSTITUTIONSSUBRECIPIENT ACTIVITIES: THE RECIPIENT DOES NOT INTEND TO SUBAWARD FUNDS.

Source notice

More from United States Department of Commerce posted in September 2025