<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/defense_logistics_agency_dla/posts/106986523862330101" -->

---
title: DYNAMOMETER (SPMYM121Q0117) – Defense Logistics Agency | Closed - MatchAwards
description: DYNAMOMETER. Defense Logistics Agency. Solicitation SPMYM121Q0117. NAICS 334519 - Other Measuring and Controlling Device Manufacturing. Total small business set-aside. Deadline 2021-09-06. DYNAMOMETER VERTICAL TEST STAND, DM2025DG, 25K LB CAPACITY 00147800001 NOTE: The requirements in DFARS...
canonical: https://matchawards.com/defense_logistics_agency_dla/posts/106986523862330101
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: DYNAMOMETER (SPMYM121Q0117) – Defense Logistics Agency | Closed
og:url: https://matchawards.com/defense_logistics_agency_dla/posts/106986523862330101
og:description: DYNAMOMETER. Defense Logistics Agency. Solicitation SPMYM121Q0117. NAICS 334519 - Other Measuring and Controlling Device Manufacturing. Total small business set-aside. Deadline 2021-09-06. DYNAMOMETER VERTICAL TEST STAND, DM2025DG, 25K LB CAPACITY 00147800001 NOTE: The requirements in DFARS...
og:image: https://matchawards.com/system/accounts/avatars/000/000/105/original/c90b43bed2221480.png?1638986263
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# DYNAMOMETER

Status

Closed (archived notice)

Agency

[Defense Logistics Agency](/defense%5Flogistics%5Fagency%5Fdla)

Office

PORTSMOUTH, USA

Notice type

Solicitation

Solicitation number

SPMYM121Q0117

NAICS

[334519 - Other Measuring and Controlling Device Manufacturing](/groups/522)

PSC

6695 - COMBINATION AND MISCELLANEOUS INSTRUMENTS

Category

[Test & Measurement Supplies (5.4)](/categories/industrial-products-and-services/test-and-measurement-supplies)

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2021-09-24

Deadline

2021-09-06

Place of performance

Portsmouth, 23709

## Description

DYNAMOMETER VERTICAL TEST STAND, DM2025DG, 25K LB CAPACITY 00147800001 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD unique identification or a DoD recognized unique identification equivalent. FOB: Destination STATEMENT OF SPECIFICATIONS STATEMENT OF SPECIFICATIONS FOR THE PROCUREMENT OF ONE VERTICAL TEST STAND DYNAMOMETER 1\. SPECIFICATIONS: 1.1\. SCOPE: Procurement for one each (1ea) 700 HP Vertical Eddy Current Dynamometer or equivalent for Norfolk Naval Shipyard Motor Section. 2\. EQUIPMENT DESCRIPTION: The equipment shall consist of one each 700 HP Vertical Eddy Current Dynamometer or equivalent. 2.1\. SALIENT CHARCTERISTICS: Machine shall have the following salient characteristics (minimum). 2.1.1\. Design / Construction: 2.1.1.1\. Dynamometer shall be a DM-2025 Eddy Current Vertical Mounted Dynamometer or equivalent. 2.1.1.2\. Dynamometer shall be capable of absorbing 700 HP at 3,600 RPM. 2.1.1.3\. Dynamometer shall be a water cooled dry gap design. 2.1.1.4\. Dynamometer shall be vertically mounted with variable height DUT test fixture or equivalent. 2.1.1.5\. Dynamometer shall have a capacity to lift and support 25,000 lbs. 2.1.1.6\. Dynamometer carcass shall be trunnion mounted with a load cell assembly. 2.1.1.7\. Dynamometer shall be equipped with a mounted 60 tooth gear and a magnetic speed sensor to measure speed. 2.1.1.8\. Dynamometer shall utilize existing water handling system and engine support equipment. 2.1.1.9\. Dynamometer shall be instrumented with a Dyne Systems Inter-Loc V Eddy Current Dynamometer Controller and accessories or equivalent. 2.1.1.10\. Dynamometer shall be built to NFPA 79 to accept 480 VAC, 3-phase, 60 Hz. 2.1.2\. Capacity: 2.1.2.1\. Power: 700 HP 2.1.2.2\. Max Torque at Base Speed: 6,120 lb-ft 2.1.2.3\. Base Speed: 600 RPM 2.1.2.4\. Rotor Inertia: 690 lb-ft2 2.1.2.5\. Coolant Required at Maximum Power: 70 gal/min 2.1.2.6\. Coolant Inlet Pressure Range: 55  100 psi 2.1.2.7\. Coolant Inlet Maximum Temperature: 90oF 2.1.2.8\. Rotation: Bi-directional STATEMENT OF SPECIFICATIONS FOR THE PROCUREMENT OF ONE VERTICAL TEST STAND DYNAMOMETER 2.1.3\. Capacity at 150 RPM: 2.1.3.1\. Maximum Power: 30 HP 2.1.3.2\. Maximum Torque: 750 lb. ft. 2.1.4\. Capacity at 300 RPM: 2.1.4.1\. Maximum Power: 170 HP 2.1.4.2\. Maximum Torque: 2200 lb. ft. 2.1.5\. Capacity at 600 RPM: 2.1.5.1\. Maximum Power: 500 HP 2.1.5.2\. Maximum Torque: 4100 lb. ft. 2.1.6\. Calibration Package: 2.1.6.1\. Package shall meet the specifications of IEEE Std 112: Torque accuracy of ±0.2% FS, Torque sensitivity of ± 0.25% FS, Engine speed accuracy of ±1 RPM 1800 RPM. 2.1.6.2\. Package shall include hardware capable of calibration to full-scale torque in CW and CCW directions. 2.1.6.3\. Package shall include load cell and linkage. 2.1.6.4\. Package shall include a speed sensor with 60-tooth tach gear. 2.1.6.5\. Package shall include a coolant safety system. 2.1.6.6\. Package shall include a calibration arm and weight hanger. 2.1.6.7\. Package shall include calibration weights. 2.1.6.8\. Package shall include a pulley assembly. 2.1.6.9\. Package shall include a small shaft end guard. 2.1.6.10\. Package shall include a dynamometer hub / companion flange. 2.1.6.11\. Package shall include a vertical test stand. 2.1.6.12\. Package shall include two torque arms. 2.1.6.13\. Package shall include four vertical supports. 2.1.6.14\. Package shall include magnetic pickup capable of being disconnected for engine speed calibration. 2.1.7\. Inter-Loc V Eddy Current Dynamometer Controller: 2.1.7.1\. Controller shall be stand-alone, multi-loop dynamometer controller 2.1.7.2\. Controller shall be capable of providing closed loop PID based control for at least three dynamometers or throttle control devices. 2.1.7.3\. Controller shall have a modular design with three slots for dyno or throttle cards. 2.1.7.4\. Controller shall have an advanced graphical tuning display. 2.1.7.5\. Controller shall have precise speed and torque control. 2.1.7.6\. Controller shall be capable of updating all control loops 500 times per second. 2.1.7.7\. Controller shall have programmable digital 24VDC inputs and outputs. STATEMENT OF SPECIFICATIONS FOR THE PROCUREMENT OF ONE VERTICAL TEST STAND DYNAMOMETER 3\. TECHNICAL MANUALS: Three (3) complete sets of technical manuals covering operation, service and maintenance, and part-listing shall be provided. 4\. QUALITY ASSURANCE PROVISIONS: Inspection and acceptance of the supplies, performed at destination by Code 983 and shall consist of type and kind; condition; operability, if readily determinable; preservation; packaging. 5\. PRESERVATION, PACKAGING AND PACKING: The equipment shall be packaged, packed and preserved for shipment to reach ultimate destination undamaged. Package shall be prominently marked NOT FOR OUTSIDE STORAGE. Yellow packaging, packing, preservation and marking are prohibited. 6\. ADDITIONAL REQUIREMENTS: 6.1\. Additional Accessories: 6.1.1\. Instrumentation Accessories: 6.1.1.1\. Accessories shall include an IL5 Operator Control Station (OCS) or equivalent. 6.1.1.2\. Accessories shall include an Inter-Loc V Dynamometer Controller Kit or equivalent 6.1.2\. Eddy Current Power Amplifier Unit (PAU) or equivalent: 6.1.2.1\. PAU shall support stand-alone operation. 6.1.2.2\. PAU shall be capable of interfacing with dynamometer controllers. 6.1.2.3\. PAU shall have diagnostic readouts including field current, input command, and power amplifier unit status and faults. 6.1.2.4\. PAU shall provide a current-regulated input and output of 0 to +10 VDC. 6.1.2.5\. PAU shall have dry contact and PCL-level I/O. 6.1.2.6\. PAU shall be equipped with integral safety inputs. 6.1.2.7\. PAU shall capable of calibration. 6.1.2.8\. PAU shall include a control power transformer. 6.1.2.9\. PAU shall have an adjustable current limit set point. 6.2\. Machine Hardware: Machines shall include any necessary lifting, leveling, and floor attachment hardware for machine installation. STATEMENT OF SPECIFICATIONS FOR THE PROCUREMENT OF ONE VERTICAL TEST STAND DYNAMOMETER 6.3\. Nameplate: A nameplate shall be permanently and securely attached to each machine, the information provided on the plate shall be as listed below. a) Nomenclature b) Manufacturers name c) Manufacturers model designation d) Manufactures serial number e) Power input (volts, total amps, phase, frequency) f) Amp rating of largest motor g) Short circuit/over-current protection rating h) Contract Number or Order Number i) National Stock Number or Plant Equipment Code j) Date of manufacture 6.4\. Operating and Maintenance Manual: Machines shall be provided with operating and Maintenance Manual (O&M), Electrical Manual, Mechanical Manual & Schematics three (3) each shall be provided with the machine and one (1) each searchable electronic copy (PDF) shall be E-mailed TPOC. 6.5\. Warranty: This machine shall be warranted against any defects in material, parts, and workmanship for 12 months after the date of installation. 7\. FACILITIES ENTRY REQUIREMENTS: 7.1\. Initial Entry: 30 days before arrival, contractor shall provide SECNAV 5512 data on all personnel expected to visit NNSY. The TPOC shall provide SECNAV 5512 forms upon request. The TPOC will endorse the SECNAV 5512 form and forward to the NNSY Pass Office. Personnel having existing valid base passes will be exempt from this requirement. Existing base passes must be valid for the duration of the expected visit. 7.2\. Vehicle Entry: The company name shall be displayed on each door of the Contractors vehicles in a manner and size that is clearly visible. All vehicles shall display a valid state license plate that complies with State Vehicle Code. Vehicles shall meet all other requirement of the State Vehicle Code, such as safety standards, and shall carry proof of insurance and state registration. Insurance and registration must be in the companys name. Passes will be issued for vehicles to enter the shipyard. A separate pass is required for entering the Controlled Industrial Area (CIA). STATEMENT OF SPECIFICATIONS FOR THE PROCUREMENT OF ONE VERTICAL TEST STAND DYNAMOMETER 7.3\. Portable Electronic Device (PED): In accordance with COMSUBLANT/COMSUBPACINST 2075.1C, the use of Portable Electron Devices (PEDs) while in or on Department of Navy Controlled Industrial Areas are prohibited. A portable electronic device (PED) is defined as any non-stationary electronic apparatus with singular or multiple capabilities of, but not limited to recording, storing, and/or transmitting data, voice, video, or photo images e.g.: cell phones, laptops, tablets and wearable devices such as fitness bands and smart watches. Non-camera cell phones are acceptable (feature phones). Where a laptop computer is required for troubleshooting and machine programming purposes, contractor must inform TPOC 2 weeks prior to visit to allow time to schedule inspections and vetting from NNSY IT department. 7.4 TPOC to provide awardee with CIA PPE Requirements for entry into the CIA. 8\. TECHNICAL POINT OF CONTACT: N/A 

<!-- mobian-agent-ad sponsored="true" id="14177ab7-bd2d-4ba5-bb50-a56c40da66c8" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/test-and-measurement-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Ted Halliday

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/86bea36b45c8413898b67c09a92a1897/view)

[More from Defense Logistics Agency posted in September 2021](/defense%5Flogistics%5Fagency%5Fdla/archive/2021-09)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"DYNAMOMETER","description":"DYNAMOMETER VERTICAL TEST STAND, DM2025DG, 25K LB CAPACITY 00147800001 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD unique identification or a DoD recognized unique identification equivalent. FOB: Destination STATEMENT OF SPECIFICATIONS STATEMENT OF SPECIFICATIONS FOR THE PROCUREMENT OF ONE VERTICAL TEST STAND DYNAMOMETER 1. SPECIFICATIONS: 1.1. SCOPE: Procurement for one each (1ea) 700 HP Vertical Eddy Current Dynamometer or equivalent for Norfolk Naval Shipyard Motor Section. 2. EQUIPMENT DESCRIPTION: The equipment shall consist of one each 700 HP Vertical Eddy Current Dynamometer or equivalent. 2.1. SALIENT CHARCTERISTICS: Machine shall have the following salient characteristics (minimum). 2.1.1. Design / Construction: 2.1.1.1. Dynamometer shall be a DM-2025 Eddy Current Vertical Mounted Dynamometer or equivalent. 2.1.1.2. Dynamometer shall be capable of absorbing 700 HP at 3,600 RPM. 2.1.1.3. Dynamometer shall be a water cooled dry gap design. 2.1.1.4. Dynamometer shall be vertically mounted with variable height DUT test fixture or equivalent. 2.1.1.5. Dynamometer shall have a capacity to lift and support 25,000 lbs. 2.1.1.6. Dynamometer carcass shall be trunnion mounted with a load cell assembly. 2.1.1.7. Dynamometer shall be equipped with a mounted 60 tooth gear and a magnetic speed sensor to measure speed. 2.1.1.8. Dynamometer shall utilize existing water handling system and engine support equipment. 2.1.1.9. Dynamometer shall be instrumented with a Dyne Systems Inter-Loc V Eddy Current Dynamometer Controller and accessories or equivalent. 2.1.1.10. Dynamometer shall be built to NFPA 79 to accept 480 VAC, 3-phase, 60 Hz. 2.1.2. Capacity: 2.1.2.1. Power: 700 HP 2.1.2.2. Max Torque at Base Speed: 6,120 lb-ft 2.1.2.3. Base Speed: 600 RPM 2.1.2.4. Rotor Inertia: 690 lb-ft2 2.1.2.5. Coolant Required at Maximum Power: 70 gal/min 2.1.2.6. Coolant Inlet Pressure Range: 55  100 psi 2.1.2.7. Coolant Inlet Maximum Temperature: 90oF 2.1.2.8. Rotation: Bi-directional STATEMENT OF SPECIFICATIONS FOR THE PROCUREMENT OF ONE VERTICAL TEST STAND DYNAMOMETER 2.1.3. Capacity at 150 RPM: 2.1.3.1. Maximum Power: 30 HP 2.1.3.2. Maximum Torque: 750 lb. ft. 2.1.4. Capacity at 300 RPM: 2.1.4.1. Maximum Power: 170 HP 2.1.4.2. Maximum Torque: 2200 lb. ft. 2.1.5. Capacity at 600 RPM: 2.1.5.1. Maximum Power: 500 HP 2.1.5.2. Maximum Torque: 4100 lb. ft. 2.1.6. Calibration Package: 2.1.6.1. Package shall meet the specifications of IEEE Std 112: Torque accuracy of ±0.2% FS, Torque sensitivity of ± 0.25% FS, Engine speed accuracy of ±1 RPM 1800 RPM. 2.1.6.2. Package shall include hardware capable of calibration to full-scale torque in CW and CCW directions. 2.1.6.3. Package shall include load cell and linkage. 2.1.6.4. Package shall include a speed sensor with 60-tooth tach gear. 2.1.6.5. Package shall include a coolant safety system. 2.1.6.6. Package shall include a calibration arm and weight hanger. 2.1.6.7. Package shall include calibration weights. 2.1.6.8. Package shall include a pulley assembly. 2.1.6.9. Package shall include a small shaft end guard. 2.1.6.10. Package shall include a dynamometer hub / companion flange. 2.1.6.11. Package shall include a vertical test stand. 2.1.6.12. Package shall include two torque arms. 2.1.6.13. Package shall include four vertical supports. 2.1.6.14. Package shall include magnetic pickup capable of being disconnected for engine speed calibration. 2.1.7. Inter-Loc V Eddy Current Dynamometer Controller: 2.1.7.1. Controller shall be stand-alone, multi-loop dynamometer controller 2.1.7.2. Controller shall be capable of providing closed loop PID based control for at least three dynamometers or throttle control devices. 2.1.7.3. Controller shall have a modular design with three slots for dyno or throttle cards. 2.1.7.4. Controller shall have an advanced graphical tuning display. 2.1.7.5. Controller shall have precise speed and torque control. 2.1.7.6. Controller shall be capable of updating all control loops 500 times per second. 2.1.7.7. Controller shall have programmable digital 24VDC inputs and outputs. STATEMENT OF SPECIFICATIONS FOR THE PROCUREMENT OF ONE VERTICAL TEST STAND DYNAMOMETER 3. TECHNICAL MANUALS: Three (3) complete sets of technical manuals covering operation, service and maintenance, and part-listing shall be provided. 4. QUALITY ASSURANCE PROVISIONS: Inspection and acceptance of the supplies, performed at destination by Code 983 and shall consist of type and kind; condition; operability, if readily determinable; preservation; packaging. 5. PRESERVATION, PACKAGING AND PACKING: The equipment shall be packaged, packed and preserved for shipment to reach ultimate destination undamaged. Package shall be prominently marked NOT FOR OUTSIDE STORAGE. Yellow packaging, packing, preservation and marking are prohibited. 6. ADDITIONAL REQUIREMENTS: 6.1. Additional Accessories: 6.1.1....","url":"https://matchawards.com/defense_logistics_agency_dla/posts/106986523862330101","identifier":"SPMYM121Q0117","category":"334519 - Other Measuring and Controlling Device Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6695 - COMBINATION AND MISCELLANEOUS INSTRUMENTS"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.4 Test \u0026 Measurement Supplies","url":"https://matchawards.com/categories/industrial-products-and-services/test-and-measurement-supplies"}],"availabilityStarts":"2021-09-24","availabilityEnds":"2021-09-06","areaServed":"Portsmouth, 23709","sameAs":"https://sam.gov/opp/86bea36b45c8413898b67c09a92a1897/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```