<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/defense_logistics_agency_dla/posts/106890264581641384" -->

---
title: DUST COLLECTOR (SPMYM121Q0118) – Defense Logistics Agency | Closed - MatchAwards
description: DUST COLLECTOR. Defense Logistics Agency. Solicitation SPMYM121Q0118. NAICS 333413 - Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing. Total small business set-aside. Deadline 2021-09-10. STATEMENT OF SPECIFICATIONS For Purchase of Dust Collector 1. SCOPE OF...
canonical: https://matchawards.com/defense_logistics_agency_dla/posts/106890264581641384
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: DUST COLLECTOR (SPMYM121Q0118) – Defense Logistics Agency | Closed
og:url: https://matchawards.com/defense_logistics_agency_dla/posts/106890264581641384
og:description: DUST COLLECTOR. Defense Logistics Agency. Solicitation SPMYM121Q0118. NAICS 333413 - Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing. Total small business set-aside. Deadline 2021-09-10. STATEMENT OF SPECIFICATIONS For Purchase of Dust Collector 1. SCOPE OF...
og:image: https://matchawards.com/system/accounts/avatars/000/000/105/original/c90b43bed2221480.png?1638986263
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# DUST COLLECTOR

Status

Closed (archived notice)

Agency

[Defense Logistics Agency](/defense%5Flogistics%5Fagency%5Fdla)

Office

PORTSMOUTH, USA

Notice type

Solicitation

Solicitation number

SPMYM121Q0118

NAICS

[333413 - Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing](/groups/475)

PSC

4460 - AIR PURIFICATION EQUIPMENT

Category

[Facility Related Materials (4.3)](/categories/facilities-and-construction/facility-related-materials)

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2021-09-07

Deadline

2021-09-10

Place of performance

Portsmouth, 23709

## Description

STATEMENT OF SPECIFICATIONS For Purchase of Dust Collector 1\. SCOPE OF WORK: The following sets forth the minimum requirements for the procurement of one (1) dust collection, fume arms & ventilation system. 2\. EQUIPMENT DESCRIPTION: the dust collector system will be dedicated to the weld fabrication tables in Bldg. 234-2nd Floor, Welding Area. 3\. SALIENT CHARACTERISTICS: 3.1\. Dust Collector (BRAHM Collector 4) 3.1.1\. Collector Body 3.1.1.1\. Construction: Fully welded heavy duty gauge steel 3.1.1.2\. Dimensions of unit: 42 (W) x 78 (D) x 69 (T) 3.1.1.3\. Motor/Blower:10HP, 3.1.1.4\. Air Flow: 6,000 CFM at 6 of static pressure 3.1.1.5\. Silencing  Internal noise abatement in motor/blower compartment to dampen noise (70-85dB at 5distance). 3.1.1.6\. Powder Coat Paint- Powder coat paint of all surface inside and out. 3.1.1.7\. Dust Tray - Dust Tray shall be provided for removal of particulate 3.1.1.8\. Flow Indicating Device 3.1.1.8.1\. The system shall have a flow indication device installed such that it is calibrated to the dust collection system in order to measure flow rate when the system is operating. This flow indicating device shall be procured from the approved flow indicating device list generated by code 106 3.1.1.9\. Filter and Pulsing Cleaning Operation 3.1.1.9.1\. Pulse Nozzles: four (4) 3.1.1.9.2\. Filter Cartridges: Four (4) PTFE cartridges, E11 rated 3.1.1.9.3\. Filter Media: 200 square feet of media in each filter at 99.5% efficiency on 0.3 micron sized particles and larger. 3.1.1.9.4\. Pulse Valve- Two (2) 1.5 pulsing valves, pulse controller with automatic or manual operation. 3.1.1.10\. Electrical Controls shall include: 3.1.1.10.1\. Motor starter, ON/OFF switch, pressure gauge, integrated disconnect switch, and overload in a NEMA 12 electrical enclosure. 3.1.1.10.2\. Electrical Requirements: 3-Phase, 460 Volt. 3.1.1.10.3\. VFD- Variable frequency drive. 3.1.1.10.4\. Fire Suppression System. 3.2\. Contractor shall provide Three (3) 8 x 10 Fume Arms: 3.2.1\. Hanging Extraction Arm 3.2.1.1\. Diameter  8 3.2.1.2\. Range  10 3.2.2\. Suction Hood 3.2.2.1\. Connection Diameter  8 3.2.2.2\. Inlet Diameter  12 3.2.2.3\. Impact Plate 3.2.2.4\. Hood Material: Aluminum/Powder (Painted) 3.2.3\. Steel Wall Bracket 3.2.3.1\. Connection diameter: 8 3.2.3.2\. Length: 16 3.2.4\. Custom Stands to support Fume Arms 3.2.4.1\. Overall length: 10 feet 3.3\. Job lot of Duct Work 3.3.1\. Job lot of duct work shall be sufficient to connect all components i.e. duct work for dust collector to fume arms and a separate duct work connecting from the dust collector to existing wall penetration venting out. 3.4\. Spark Coolers 3.4.1\. One (1) Spark Coolers shall be included in the main duct. 4\. QUALITY ASSURANCE: NNSY shall be responsible for the performance of all inspection requirements specified herein. The machine and all ancillary equipment shall be completely conform to the requirements specified herein prior to the contractor requesting origin inspection from Government. The Government reserves the right to perform any inspections set forth in the purchase description where such inspections are deemed necessary to assure supplies and services conform to prescribed equirements. 5\. INSTALLATION: N/A 6\. TRAINING: N/A. 7\. OPERATOR / MAINTENANCE / REPAIR MANUALS: 7.1\. The equipment shall be furnished with two (2) hard copies of the manufactures standard Operation, Maintenance, and Repair Manual(s).8\. LIFTING AND HANDLING: N/A9\. TECHNICAL POC: N/A 8\. LIFTING AND HANDLING: N/A 9\. TECHNICAL POC: N/A 

<!-- mobian-agent-ad sponsored="true" id="150d1f79-3ef6-4456-b908-1f51c250bdf9" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-materials?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1a98f6d840be4bbb83bf547236a9a406/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c530c4f0a8b14a8485077220b0abe735/download)
* [Attachment 3](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/15dc654f51c240da93240da12615b5b8/download)
* [Attachment 4](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8b7f351eabbc49f68a86f6c7a87a4783/download)

## Contacts

* Ted Halliday

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/e6ddfda3311b4b9f9155fc3a3de1ccf6/view)

[More from Defense Logistics Agency posted in September 2021](/defense%5Flogistics%5Fagency%5Fdla/archive/2021-09)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"DUST COLLECTOR","description":"STATEMENT OF SPECIFICATIONS For Purchase of Dust Collector 1. SCOPE OF WORK: The following sets forth the minimum requirements for the procurement of one (1) dust collection, fume arms \u0026 ventilation system. 2. EQUIPMENT DESCRIPTION: the dust collector system will be dedicated to the weld fabrication tables in Bldg. 234-2nd Floor, Welding Area. 3. SALIENT CHARACTERISTICS: 3.1. Dust Collector (BRAHM Collector 4) 3.1.1. Collector Body 3.1.1.1. Construction: Fully welded heavy duty gauge steel 3.1.1.2. Dimensions of unit: 42 (W) x 78 (D) x 69 (T) 3.1.1.3. Motor/Blower:10HP, 3.1.1.4. Air Flow: 6,000 CFM at 6 of static pressure 3.1.1.5. Silencing  Internal noise abatement in motor/blower compartment to dampen noise (70-85dB at 5distance). 3.1.1.6. Powder Coat Paint- Powder coat paint of all surface inside and out. 3.1.1.7. Dust Tray - Dust Tray shall be provided for removal of particulate 3.1.1.8. Flow Indicating Device 3.1.1.8.1. The system shall have a flow indication device installed such that it is calibrated to the dust collection system in order to measure flow rate when the system is operating. This flow indicating device shall be procured from the approved flow indicating device list generated by code 106 3.1.1.9. Filter and Pulsing Cleaning Operation 3.1.1.9.1. Pulse Nozzles: four (4) 3.1.1.9.2. Filter Cartridges: Four (4) PTFE cartridges, E11 rated 3.1.1.9.3. Filter Media: 200 square feet of media in each filter at 99.5% efficiency on 0.3 micron sized particles and larger. 3.1.1.9.4. Pulse Valve- Two (2) 1.5 pulsing valves, pulse controller with automatic or manual operation. 3.1.1.10. Electrical Controls shall include: 3.1.1.10.1. Motor starter, ON/OFF switch, pressure gauge, integrated disconnect switch, and overload in a NEMA 12 electrical enclosure. 3.1.1.10.2. Electrical Requirements: 3-Phase, 460 Volt. 3.1.1.10.3. VFD- Variable frequency drive. 3.1.1.10.4. Fire Suppression System. 3.2. Contractor shall provide Three (3) 8 x 10 Fume Arms: 3.2.1. Hanging Extraction Arm 3.2.1.1. Diameter  8 3.2.1.2. Range  10 3.2.2. Suction Hood 3.2.2.1. Connection Diameter  8 3.2.2.2. Inlet Diameter  12 3.2.2.3. Impact Plate 3.2.2.4. Hood Material: Aluminum/Powder (Painted) 3.2.3. Steel Wall Bracket 3.2.3.1. Connection diameter: 8 3.2.3.2. Length: 16 3.2.4. Custom Stands to support Fume Arms 3.2.4.1. Overall length: 10 feet 3.3. Job lot of Duct Work 3.3.1. Job lot of duct work shall be sufficient to connect all components i.e. duct work for dust collector to fume arms and a separate duct work connecting from the dust collector to existing wall penetration venting out. 3.4. Spark Coolers 3.4.1. One (1) Spark Coolers shall be included in the main duct. 4. QUALITY ASSURANCE: NNSY shall be responsible for the performance of all inspection requirements specified herein. The machine and all ancillary equipment shall be completely conform to the requirements specified herein prior to the contractor requesting origin inspection from Government. The Government reserves the right to perform any inspections set forth in the purchase description where such inspections are deemed necessary to assure supplies and services conform to prescribed equirements. 5. INSTALLATION: N/A 6. TRAINING: N/A. 7. OPERATOR / MAINTENANCE / REPAIR MANUALS: 7.1. The equipment shall be furnished with two (2) hard copies of the manufactures standard Operation, Maintenance, and Repair Manual(s).8. LIFTING AND HANDLING: N/A9. TECHNICAL POC: N/A 8. LIFTING AND HANDLING: N/A 9. TECHNICAL POC: N/A","url":"https://matchawards.com/defense_logistics_agency_dla/posts/106890264581641384","identifier":"SPMYM121Q0118","category":"333413 - Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"4460 - AIR PURIFICATION EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.3 Facility Related Materials","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-materials"}],"availabilityStarts":"2021-09-07","availabilityEnds":"2021-09-10","areaServed":"Portsmouth, 23709","sameAs":"https://sam.gov/opp/e6ddfda3311b4b9f9155fc3a3de1ccf6/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```