ClickCease LI-COR LI-7820 N2O/H2O Trace Gas Analyzer, Analyzer T-split… | Closed - MatchAwards

LI-COR LI-7820 N2O/H2O Trace Gas Analyzer, Analyzer T-split Tubing, and 3-year all inclusive service agreement

Status
Closed, the response deadline passed on Oct 28, 2024
Agency
Agricultural Research Service
Office
STONEVILLE, USA
Notice type
Sources Sought
Solicitation number
12405B25Q0007
NAICS
334516 - Analytical Laboratory Instrument Manufacturing
PSC
6640 - LABORATORY EQUIPMENT AND SUPPLIES
Category
Test & Measurement Supplies (5.4)
Posted
2024-10-21
Deadline
2024-10-28
Place of performance
Houma, Louisiana 70360, UNITED STATES

Description

1. Type of Notice: This is a SOURCES SOUGHT NOTICE ONLY. This is NOT a solicitation for proposals or quotes and does not obligate the Government to award a contract. This notice is for informational and planning purposes only and shall not be construed as a solicitation or an obligation or commitment by the Government, nor is it a Request for Proposal (RFQ) at this time. Responses to this Notice must be in writing.

2. Purpose: The purpose of this Sources Sought Notice is to conduct market research to determine, in particular; the capability of sam.gov registered Small Business entities to provide the commercial supply described below. ARS will accept responses from ALL socioeconomic categories in order to gain a more complete understanding of the market for these supplies.

3. Requirement Description:

3.1. Requirement Location: See Place of Performance above.

3.2. The USDA-ARS has a need for a Trace Gas Analyzer. 

1.0 Specifications Description:

Measurement Technique: OF-CEAS (Optical Feedback – Cavity Enhanced Absorption Spectroscopy)

Measurement Rate: 1 sample per second (1 Hz)

Optical Cavity Volume: 6.41 cm3

Flow Rate:

250 sccm nominally in Standard Configuration

150 sccm nominally in High Altitude Configuration

70 sccm nominally in Reduced Flow Rate Configuration with installed kit

Total Weight: 10.5 kg (including batteries)

Case Dimensions: 51 cm × 33 cm × 18 cm (L × W × H)

Operating Temperature Range: -25 °C to 45 °C (without solar load, under normal operating conditions)

Operating Humidity Range: 0 to 85% RH (non-condensing, without solar load, under normal operating conditions)

Sample Line Humidity Range: 0 to 99.9% non-condensing

Operating Pressure Range:

70 to 110 kPa in Standard and Reduced Flow Rate Configurations

50 to 110 kPa in High Altitude Configuration

Connectivity: Ethernet and Wi-Fi (not available in some countries)

Wi-Fi Compatibility: 2.4 GHz, 802.11 a/b/g/n/ac

Power Consumption:

Steady State Operation: 22 Watts at 25 °C without batteries charging

Warmup: Up to 65 W without batteries charging; up to 100 W with batteries charging

Off: Up to 2.3 W when powered from pins 3 and 4 without batteries charging; up to 0.2 W when powered from pins 1 and 5 without batteries charging

Power Supply Requirements:

Pins 1 and 5 (24 VDC Input): Minimum 6 A at 24 V

Pins 3 and 4 (10.5 to 33 VDC Input): Minimum 14 A at 10.5 VDC; 6 A at 24 VDC

Power Supply: Universal Power Adapter (Input: 100 to 240 VAC, 50-60 Hz; Output: 24 VDC)

Battery Life: 8 hours typical with 2 batteries

LI-COR 7820

Quantity: 1

Unit Type: Each

Minimum Requirements: High-precision N2O analyzer that is portable for use in soil flux measurements and atmospheric monitoring.

Analyzer T-Split Tubing 9982-073

Quantity: 1

Unit Type: Each

Minimum Requirements: Use LI-7820 with both the LI-780 and Smart Chamber at the same time

Incidental Services:

3-year Service agreement to include: free replacement or extensive damage, water damage coverage, impact damage coverage, voltage damage coverage, defective parts coverage, priority service, free shipping from Li-Cor to customer, free calibration, free cavity replacements for trace gas analyzers

Additional Requirements  

Warranty against manufacturing defects. 