<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/agricultural_research_service/posts/108668230046486201" -->

---
title: Supply and Install Chemical Storage Building | Closed - MatchAwards
description: Supply and Install Chemical Storage Building. Agricultural Research Service. Solicitation 12405B22Q0240. NAICS 236210 - Industrial Building Construction. Total small business set-aside. Deadline 2022-07-27. A site visit has been scheduled for this project. It will be held on Wednesday, July 20th,...
canonical: https://matchawards.com/agricultural_research_service/posts/108668230046486201
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Supply and Install Chemical Storage Building | Closed
og:url: https://matchawards.com/agricultural_research_service/posts/108668230046486201
og:description: Supply and Install Chemical Storage Building. Agricultural Research Service. Solicitation 12405B22Q0240. NAICS 236210 - Industrial Building Construction. Total small business set-aside. Deadline 2022-07-27. A site visit has been scheduled for this project. It will be held on Wednesday, July 20th,...
og:image: https://matchawards.com/system/accounts/avatars/000/000/095/original/8e09f42f1a429db3.jpg?1639055475
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Supply and Install Chemical Storage Building

Status

Closed (archived notice)

Agency

[Agricultural Research Service](/agricultural%5Fresearch%5Fservice)

Office

STONEVILLE, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

12405B22Q0240

NAICS

[236210 - Industrial Building Construction](/groups/211)

PSC

5670 - BUILDING COMPONENTS, PREFABRICATED

Category

[Construction Related Materials (4.1)](/categories/facilities-and-construction/construction-related-materials)

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2022-07-18

Deadline

2022-07-27

Place of performance

New Orleans, 70124

## Description

A site visit has been scheduled for this project. It will be held on Wednesday, July 20th, at 2:00 PM CST. Please send the company name and the name of personnel requesting to attend to lynn.hults@usda.gov by 4:00PM Tuesday, July 19th CST. This solicitation has been extended until Wednesday July 27, 2022\. Questions can be provided until Monday, 25, 2022\. Question 1: Please confirm that a Factory Mutual Approval label is required with NRTL Certified components as the government requires for their projects. Please advise who was used as the basis of design since these are not typical specifications required for FM Approved prefabricated chemical storage buildings shipped to New Orleans, LA. Answer 1: While doing market research, we found multiple vendors and manufacturers that could provide appropriate and acceptable buildings for our needs. All these buildings were indicated to have the FM approval rating. It should not be a problem to meet all our specs and obtain the FM approval label, however we are not requiring all those standards to be met. Question 2: You referenced a 1 fire rated partition wall needed. The only option for partition walls is non-fire-rated, 2 hour fire-rated and 4 hour fire-rated partition walls approved for FM approved buildings. Please confirm what fire-rating is required for the partition wall since a 1 hour fire-rated partition wall is not an NRTL Certified option and not approved for FM Approved buildings. Answer 2: The 1 mentioned in the SOW was indicating a quantity of ONE partition wall and was not indicating fire rating. We require that the fire partition wall be rated at three hours. Question 3: 4 hour fire-rated construction should always be bi-directional fire protection for FM Approved buildings since uni-directional fire-rated walls do not protect from fires entering the buildings from outside sources. Answer 3: We require a uni-directional system as a basic bid or a minimum. Question 4: The 140 MPH wind load requirement will need to be required for the entire building including all walls, ceiling and sump with wind rated air inlets and double doors required to meet the wind load needed. Without these components, your building will not be wind rated and the door will have increased corrosion since standard double doors have weep holes for condensation and wind will cause moisture up the weep holes and the door to corrode quickly near the bottom edge. This will reduce the life of your building considerable and the double door cannot be replaced in the field when corrosion appears since the frame is welded into place per FM requirements. Adding wind load structure to the walls only will not meet the wind load requirement for New Orleans, LA and the building cannot be labeled with a 140 MPH wind load per code compliance. Answer 4: The proposed building is required to meet all federal, state, and local codes and to be stamped by a PE licensed Engineer. Question 5: A PE stamped submittal should be included to validate the 140 MPH wind load requirement has been met by supplying PE Stamped drawings and calculations by a LA licensed PE. Without this requirement any one can state that their building meets the wind load requirement and you have no way to validate the option since it is in the wall structure and cannot be confirmed by visual inspection at delivery with no submittal drawings included to validate your requirements. Answer 5: We are aware of the PE stamp requirement. This must be handled and completed by the contractor and the price included in the bid. Only the contractor/manufacturer has access to the detailed plans and drawings for the building, which will be required for the PE stamp. Any submittal for consideration must have the stamp present. Question 6: Please confirm the building size needed since your only provided the pad size and not the storage requirements needed. Without listing the building size and storage capacity needed, anyone can quote a much smaller building than needed and be compliant to your specification since only maximum building dimensions are listed. This not recommended if you want bidders to quote comparable prefabricated chemical storge buildings. Answer 6: Building size varies between manufacturers, so we cannot specify exact building size. We would like the largest building that fits appropriately on our concrete pad, considering required tie downs and any other exterior accessories that require space. The concrete pad is 1511 x 94. Equipment research shows that buildings tend to come in \~16 and \~14 lengths. A 16 building will NOT fit on the pad, so we will likely need a building one size down, in the 14 range. Contractors are encouraged to measure the existing pad during the site visit and propose the largest unit that can fill pad. Question 7: You will need to specify that a 2.5 fire department hose connection be included to provide the connection to the sprinklers to deluge the building. Without this option, there is no way for the fire-fighting response for deluge. Also, a sump drain with ball check value is typically needed to avoid overflowing the sump during firefighting deluge. Answer 7: The sprinkler system must have an exterior 2-1/2 NHT (National Hose Thread) brass fitting with cap. Question 8: Mechanical ventilation will be required since natural ventilation will not provide the 6 air changes per hour required for storing flammables. Your specification references passive ventilation and a mechanical ventilation system is required for storing flammables/combustible to remove the vapors before personnel enter the building. Answer 8: An explosion proof mechanical exhaust fan must be included. The system must be able to automatically shut down if a fire occurs. Question 9: Please confirm how much stainless shelving required since it was not included in your specification. Answer 9: We will need 9 shelves per side of the unit, for a total of 18 shelves for the entire building. (additional shelving is acceptable if that is standard) Question 10: Please confirm the electrical supply voltage and phase available since it was not included in your specification. Answer 10: Electrical connection is standard 120/208 V, single phase. We do not require a step down transformer. Question 11: Please confirm that your specification includes a horn and strobe alarm for the dry chemical fire suppression system since it was unclear what the alarm was supporting from the statement about bell and lights. The dry chemical fire suppression system comes standard with a bell but will be replaced if a horn and strobe are needed. Answer 11: The system must be equipped with a means for remote annunciation system, which could include a bell, a horn, and a strobe light. There must be some sort of exterior audible alarm. This is a Combined Synopsis/Solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. Solicitation number 12405B22Q0240 is issued as a request for quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-83\. The associated NAICS code is 236210 (Industrial Building Construction), with a small business size standard of $39.5 Million. USDA, ARS, SRRC 1100 Allen Toussaint BLVD New Orleans, LA 70124 Is looking for procurement for Supply and Install Chemical Storage Building that fits into the associated Statement of Work. The Government anticipates award of a Firm Fixed Price contract. Each offer must show a breakdown giving price of each element, provide descriptive literature or information showing that the offered items meet all parts of the Equipment Requirements. Vendors responding to this announcement shall submit their quote in accordance with FAR 52.212-1\. Submission of quote shall include the following: (1) Technical Specifications and (2) Price (to include shipping). Electronic submissions are preferred. Please email all quotes to lynn.hults@usda.gov. NO LATE QUOTES WILL BE ACCEPTED. The basis for award is Lowest Price Technically Acceptable. "LPTA" means the expected outcome of the acquisition that result from selection of the technically acceptable proposal with the lowest evaluated price. Pursuant to FAR 52.212-2, the criteria for evaluation are: (1) Technical Specifications, (2) Price, and must also have satisfactory Past Performance. INSPECTON AND ACCEPTANCE TERMS: Supplies will be inspected by requiring office's technical representative and accepted at destination. The following Federal Acquisition Regulation (FAR) and the Department of Agriculture Acquisition Regulation (AGAR) provisions and clauses apply to this acquisition: FAR 52.202-1 Definitions; FAR 52.203-5 Covenant Against Contingent Fees; FAR 52.203-6 Restriction on Subcontractor Sales to the Government; FAR 52.203-7 Anti-Kickback Procedures; FAR 52.203-17 Contractor Employee Whistleblower Rights and Requirement to Inform Employees of Whistleblower Rights; FAR 52.204-7 Central Contractor Registration; FAR 52.204-10 Reporting Executive Compensation and First-Tier Subcontract Awards; FAR 52.204-14 Service Contract Reporting Requirements; FAR 52.204-16 Commercial and Government Entity Code Reporting; FAR 204-17 Ownership or Control of Offeror; FAR 52.204-18 Commercial and Government Entity Code Reporting; AGAR 452.204-70 Inquiries; FAR 204-19 Incorporation by Reference of Representations and Certifications; FAR 52.209-6 Protecting the Government's Interests when Subcontracting with Contractors Debarred, Suspended or Proposed for Debarment; FAR 52.209-10 Prohibition on Contracting with Inverted Domestic Corporations; AGAR 452.209-71 Assurance Regarding Felony Conviction or Tax Delinquent Status for Corporate Applicants; FAR 52.212-1 Instructions to Offers-Commercial Items; FAR 52.212-2 Evaluation- Commercial Items (filled in as follows: Technical specifications and price); FAR 52.212-4 Contract Terms and Conditions-Commercial Items; FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes of Executive Orders-Commercial Items; FAR 52.216-24 Limitation of Government Liability; FAR 216.25 Contract Definitization; FAR 52.219-6 Notice of Total Small Business Set-Aside; FAR 52.219-28 Post Award Small Business Program Re-representation; AGAR 452.219-70 Size Standard and NAICS Code Information; FAR 52.222-3 Convict Labor; FAR 52.222-17 Non-displacement of Qualified Workers; FAR 52.222-21 Prohibition of Segregated Facilities; FAR 52.222-26, Equal Opportunity Employment; FAR 52.222-36 Affirmative Action for Workers with Disabilities; FAR 52.222-50 Combating Trafficking in Persons; FAR 52.223-18 Encouraging Contractor Policy to Ban Text Messaging While Driving; FAR 52.225-13 Restrictions on Certain Foreign Purchases; FAR 52.225-25 Prohibitions on Contracting with Entities Engaging in Certain Activities or Transactions Relating to Iran-Reps and Certs; FAR 52.232-1 Payments; FAR 52.232-33 Payment by Electronic Funds Transfer-Central Contractor Registration; FAR 52.232-39 Unforceability of Unauthorized Obligations; FAR 52.233-2 Service of Protest; FAR 52.233-3 Protest After Award; FAR 52.233-4 Applicable Law for Breach of Contract; FAR 52.243-FAR 52.244- 6 Subcontractors for Commercial Items; FAR 52.252-1 Solicitations Provisions Incorporated by Reference; FAR 52.243-1, Alternate 1, Changes  Fixed Price; FAR 52.243-4 Changes; FAR 52.249-2 Termination for Convenience of the Government (Fixed Price); 52.252-2 Clauses Incorporated by Reference. To be eligible for an award, all contractors must be registered in the System for Award Management (SAM). A contractor can contact SAM by calling 1-866-606-8220 or e-mail at www.sam.gov. NO EXCEPTIONS. A DUNS (Dun and Bradstreet) number is required in order to register. All invoices shall be submitted and paid electronically. Quotes must be received no later than July 22, 4:00pm Central Standard Time. Questions regarding this combined synopsis/solicitation are due no later than 3:00 PM CST on Wednesday July 20, 2022\. Answers to any questions received by that time will be posted as an amendment to this combined synopsis/solicitation. 

<!-- mobian-agent-ad sponsored="true" id="6b3c7daa-8fe5-4676-bee9-8ebe75aabf89" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/construction-related-materials?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/89f5b840343d4df580f72aeee9ab5a75/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/94a538c59b2c4630ad5e17b5c0b0e9d9/download)

## Contacts

* Lynn Hults

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/136e8ddccfa14a10b3ae7f852c37715f/view)

[More from Agricultural Research Service posted in July 2022](/agricultural%5Fresearch%5Fservice/archive/2022-07)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)
* [Construction Government Contracts Available Now](/contracts/construction)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Supply and Install Chemical Storage Building","description":"A site visit has been scheduled for this project. It will be held on Wednesday, July 20th, at 2:00 PM CST. Please send the company name and the name of personnel requesting to attend to lynn.hults@usda.gov by 4:00PM Tuesday, July 19th CST. This solicitation has been extended until Wednesday July 27, 2022. Questions can be provided until Monday, 25, 2022. Question 1: Please confirm that a Factory Mutual Approval label is required with NRTL Certified components as the government requires for their projects. Please advise who was used as the basis of design since these are not typical specifications required for FM Approved prefabricated chemical storage buildings shipped to New Orleans, LA. Answer 1: While doing market research, we found multiple vendors and manufacturers that could provide appropriate and acceptable buildings for our needs. All these buildings were indicated to have the FM approval rating. It should not be a problem to meet all our specs and obtain the FM approval label, however we are not requiring all those standards to be met. Question 2: You referenced a 1 fire rated partition wall needed. The only option for partition walls is non-fire-rated, 2 hour fire-rated and 4 hour fire-rated partition walls approved for FM approved buildings. Please confirm what fire-rating is required for the partition wall since a 1 hour fire-rated partition wall is not an NRTL Certified option and not approved for FM Approved buildings. Answer 2: The 1 mentioned in the SOW was indicating a quantity of ONE partition wall and was not indicating fire rating. We require that the fire partition wall be rated at three hours. Question 3: 4 hour fire-rated construction should always be bi-directional fire protection for FM Approved buildings since uni-directional fire-rated walls do not protect from fires entering the buildings from outside sources. Answer 3: We require a uni-directional system as a basic bid or a minimum. Question 4: The 140 MPH wind load requirement will need to be required for the entire building including all walls, ceiling and sump with wind rated air inlets and double doors required to meet the wind load needed. Without these components, your building will not be wind rated and the door will have increased corrosion since standard double doors have weep holes for condensation and wind will cause moisture up the weep holes and the door to corrode quickly near the bottom edge. This will reduce the life of your building considerable and the double door cannot be replaced in the field when corrosion appears since the frame is welded into place per FM requirements. Adding wind load structure to the walls only will not meet the wind load requirement for New Orleans, LA and the building cannot be labeled with a 140 MPH wind load per code compliance. Answer 4: The proposed building is required to meet all federal, state, and local codes and to be stamped by a PE licensed Engineer. Question 5: A PE stamped submittal should be included to validate the 140 MPH wind load requirement has been met by supplying PE Stamped drawings and calculations by a LA licensed PE. Without this requirement any one can state that their building meets the wind load requirement and you have no way to validate the option since it is in the wall structure and cannot be confirmed by visual inspection at delivery with no submittal drawings included to validate your requirements. Answer 5: We are aware of the PE stamp requirement. This must be handled and completed by the contractor and the price included in the bid. Only the contractor/manufacturer has access to the detailed plans and drawings for the building, which will be required for the PE stamp. Any submittal for consideration must have the stamp present. Question 6: Please confirm the building size needed since your only provided the pad size and not the storage requirements needed. Without listing the building size and storage capacity needed, anyone can quote a much smaller building than needed and be compliant to your specification since only maximum building dimensions are listed. This not recommended if you want bidders to quote comparable prefabricated chemical storge buildings. Answer 6: Building size varies between manufacturers, so we cannot specify exact building size. We would like the largest building that fits appropriately on our concrete pad, considering required tie downs and any other exterior accessories that require space. The concrete pad is 1511 x 94. Equipment research shows that buildings tend to come in ~16 and ~14 lengths. A 16 building will NOT fit on the pad, so we will likely need a building one size down, in the 14 range. Contractors are encouraged to measure the existing pad during the site visit and propose the largest unit that can fill pad. Question 7: You will need to specify that a 2.5 fire department hose connection be included to provide the connection to the sprinklers to deluge the building. Without this option, there is...","url":"https://matchawards.com/agricultural_research_service/posts/108668230046486201","identifier":"12405B22Q0240","category":"236210 - Industrial Building Construction","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"5670 - BUILDING COMPONENTS, PREFABRICATED"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.1 Construction Related Materials","url":"https://matchawards.com/categories/facilities-and-construction/construction-related-materials"}],"availabilityStarts":"2022-07-18","availabilityEnds":"2022-07-27","areaServed":"New Orleans, 70124","sameAs":"https://sam.gov/opp/136e8ddccfa14a10b3ae7f852c37715f/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```